Pneumatic Shield Box
TC-5910DP
With wide frequency band supporting range from 100 to 6000 MHz, the TESCOM Shield Box can be applied to most of the current and future wireless communication technologies such as GSM, WCDMA, WiMAX, LTE, GNSS, Bluetooth, and Wi-Fi. Therefore, the Shield Box can be used for mobile device measurement using multi-frequency bands without limitations and is ideal for mobile device measurement by maintaining stable and effective shielding performance in all frequency bands.
Key Features
  • Reliable RF Shielding

  • Pneumatic control of lid open-close and optional test fixture motions

  • EMI filters on all Data and DC lines

  • Easily customizable to meet various test needs

  • RS-232C Remote Control


Specifications

◈ Mechanical Specifications


  • Line voltage : DC 24 V, Max. 2 A

  • Power consumption : Max. 1.5 W

  • Remote control : RS-232C, 3 wire, DB9(s)

  • Air connection

    - Main connector : 6 mm OD hose, one-touch push-on fitting

    - Fixture control connector connector : 4 mm OD hose, one-touch push-on fitting

    - Input air pressure : 5 to 10 bar

  • Dimensions

    - Inside : 142(W) x 243(D) x 139(H) mm

    - Outside : 218(W) x 375(D) x 195(H) mm, lid closed. 410(D) x 360(H) mm, lid open.

  • Weight : Approx. 7 kg

  • Packing (The size or weight of a package may vary on how to pack a package.) 

     - Size : 370(W) x 460(D) x 280(H) mm

    - Weight : Approx. 8 kg


◈ Dimensions


    • TC-5910DP Outer Dimension 

 

          

             


 



    • TC-5910DP Inner Dimension

        

   


 




◈ Typical RF Shielding

   

The shielding effectiveness below is measured when the blank panel is mounted; other I/O interface panel results a different shielding effectiveness of the shield box.

 

   Frequency / Shielding effectiveness (dB)

   - 100 to 2000 MHz : > 70 dB

   - 2000 to 3000 MHz : > 70 dB

   - 3000 to 6000 MHz : > 60 dB

Ordering Information

◈ TC-5910DP: Pneumatic Shield Box (Including accessories below)


▷ Test Report

▷ RF Cable, RG400S, N(m) to N(m) cable, 1 m, 1 pc

▷ DATA Cable, DB9(s) to DB9(s) 2 m, 1 pc

▷ Air Coupler, 1 pc

▷ Switching Power Supply, 1 pc


◈ Pre-Configured I/O Interface Panel


 

※ M591012B : Data Interface Panel


▷ two(2) N(f) outside and SMA(f) inside

▷ one(1) DB25(p) outside and DB25(s) inside, 1000 pF Pi filter

▷ one(1) USB 2.0 outside and inside




※ M591016B : Data Interface Panel


▷ two(2) N(f) outside and SMA(f) inside

▷ one(1) DB25(p) outside and DB25(s) inside, 1000 pF Pi filter

▷ one(1) DB9(p) outside and DB9(s) inside, 100 pF Pi filter

▷ one(1) USB 2.0 outside and inside



※ M591017B : Data Interface Panel


▷ three(3) SMA(f) outside and SMA(f) inside

▷ one(1) DB25(p) outside and DB25(s) inside, 1000 pF Pi filter

▷ one(1) DB9(p) outside and DB9(s) inside, 100 pF Pi filter

▷ one(1) USB 2.0 outside and inside

▷ one(1) DC Power Adaptor


※ M591023A : Data Interface Panel


▷ four(4) N(f) outside and SMA(f) inside

▷ two(2) USB 2.0 outside and inside





※ M591047A : Data Interface Panel


▷ three(3) SMA(f) outside and SMA(f) inside

▷ one(1) DB25(p) outside and DB25(s) inside, 1000 pF Pi filter

▷ two(2) USB 3.1 Gen 1 outside and inside

▷ one(1) DC Power Adaptor




◈ Customized I/O Interface Panel




Customized I/O Interface Panel is available by selecting below I/O interfaces and combine.
Please contact Tescom sales team or your local distributor.


  • Filtered D-Sub Adaptors



    • DB25 1000PF, 3409-0009-1
    • DB25 100PF, 3409-0014-1
    • DB9 1000PF, 3409-0008-1
    • DB9 100PF, 3409-0010-1


  • Filtered Data Adaptors



    • USB 2.0 Adaptor, 3409-0018A-3
    • USB 3.0 Adaptor(Active), 3409-0042A-2
    • RJ-45 Adaptor, 3409-0022A


  • Filtered Power Adaptors - AC/DC



    • DC Power Adaptor, 3406-0004A
    • DC Power Adaptor, Banana Jack Type, 3406-0005A & 3406-0006A 
    • AC Power Adaptor, 3103-0009A


  • RF Connectors

    • RF, N-SMA Connector, 3408-0038
    • RF, SMA-SMA Connector, 3408-0039



Download
[Data Sheet]
The data sheet of TC-5910DP Pneumatic Shield Box containing key features, specifications and ordering information.
[Manual]
A user manual of TC-5910DP containing detailed guide from set-up to maintenance.